Cause:

Assuming that the number of rounds is greater than 1, InTime may stop after just 1 round because the following conditions are not satisfied:

  • There are no *valid results from the 1st round.
    Note that results which has grey text are not considered valid results. These are timing estimates when the compilation is stopped prematurely. (See below)
    invalid_results
  • Errors happen during the results download and is unable to go to the next round. Examples of such errors may be disk space.
  • Timing Goal is met.